DETAILS


Automotive Twin Sheath V90HT


CONSTRUCTION

  • Conductors Plain annealed copper conductors (PCW) to AS/NZS1125
  • Insulation PVC UV Stabilised V90HT to AS3808:2000
  • Sheath PVC UV Stabilised V90HT to AS3808:2000
  • Voltage AC 50V / DC 120V to AS/NZS 3000:2000
  • Colour Black Sheath with Red & Black Cores

PACKAGING

  • Standard Length Cable Packing 30m, 100m, 500m
  • Standard Cable Markings None

FEATURES

  • RoHS Compliant
  • Temperature Rating 90ºC
  • 99.9% OFHC (Oxygen Free High Conductivity) Copper which does not show any brittleness

APPLICATIONS

  • General Automotive Wiring
  • Trailer Wiring
  • Garden Lighting
CODE No
Strands/ø
mm
Nominal
Area
mm²
Industry
Equivalent
mm
Amps ** Insulation
Thickness
mm
Max DC
Resistence
@20°C
Nominal
OD
mm
Mass
Kg/100m
2mm 7/0.32 0.56 2.0 10 0.50 33.76 2.75x4.5 2.32
3mm 16/0.30 1.13 3.0 16 0.45 16.50 3.40x6.8 4.09
4mm 26/0.30 1.84 4.0 22 0.55 10.15 3.90x6.6 5.70
5mm 41/0.30 2.90 5.0 29 0.65 6.43 4.60x8.0 8.40
6mm 65/0.30 4.59 6.0 40 0.75 4.06 5.50x9.3 12.56
8mm 112/0.30 7.92 8 B&S 74 1.20 2.40 8.0x13.4 14.08
14mm 189/0.30 13.36 6 B&S 100 1.20 1.40 9.40x16.2 37.50

 

 

 

 

 

 

 

 

 

 

 

Please Note**

  • NOT SUITABLE FOR CONNECTIONS TO MAINS POWER SUPPLY.
  • AMP Ratings are based on JASO D609:2001 single core AMBIENT TEMPERATURE AT 30° C.
  • For Current Ratings refer to table Automotive Duty Cycle @ 50V DC